Bronchoscope-Related “Superbug” Infections

Published:August 14, 2019DOI:https://doi.org/10.1016/j.chest.2019.08.003
      Several recent cases associating cleaned and high-level disinfected duodenoscopes with outbreaks of carbapenem-resistant Enterobacteriaceae (CRE) and related multidrug-resistant organisms (MDROs) may cause bronchoscopists, pulmonologists, and other stakeholders to inquire about the effectiveness of today’s practices for reprocessing flexible bronchoscopes. The primary objectives of this study were to address this question and investigate the risk of bronchoscopes transmitting infections of CRE and related MDROs. The published literature and the US Food and Drug Administration’s medical device database of adverse events were searched beginning in 2012, when endoscopy first emerged as a recognized risk factor for transmission of CRE. The Internet was also searched during this same time frame to identify other relevant cases. Several cases associating reprocessed bronchoscopes with infections of CRE or a related MDRO were identified. This study’s findings suggest that bronchoscopes may pose an underrecognized potential for transmission of CRE and related MDROs, warranting greater public awareness, enhanced preventive measures, and updated reprocessing guidance. This study’s data also suggest that the cleaning and high-level disinfection of bronchoscopes performed in accordance with published guidelines and manufacturer instructions may not always be sufficiently effective to eliminate this risk. Several factors were identified that can adversely affect a bronchoscope’s reprocessing and pose a risk of transmission of these multidrug-resistant bacteria, including use of a damaged or inadequately serviced bronchoscope, and formation of an inaccessible biofilm. Recommendations are provided to improve the safety of flexible bronchoscopes, including supplementing their reprocessing with an enhanced measure such as sterilization when warranted, and strict adherence to a periodic servicing and maintenance schedule consistent with the bronchoscope manufacturer’s instructions.

      Key Words

      Abbreviations:

      AER (automated endoscope reprocessor), CDC (Centers for Disease Control and Prevention), CRE (carbapenem-resistant Enterobacteriaceae), FDA (US Food and Drug Administration), HLD (high-level disinfection), MAUDE (Manufacturer and User Facility Device Experience Database), MDRO (multidrug-resistant organism)
      To read this article in full you will need to make a payment
      Subscribe to CHEST
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Muscarella L.F.
        Risk of transmission of carbapenem-resistant Enterobacteriaceae and related "superbugs" during gastrointestinal endoscopy.
        World J Gastrointest Endosc. 2014; 6: 457-474
        • Epstein L.
        • Hunter J.C.
        • Arwady M.A.
        • et al.
        New Delhi metallo-β-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes.
        JAMA. 2014 Oct 8; 312: 1447-1455
        • United States Senate Health, Education, Labor and Pensions (HELP) Committee
        Patty Murray, Ranking Member. Preventable Tragedies: Superbugs and How Ineffective Monitoring of Medical Device Safety Fails Patients.
        January 13,. 2016; (Accessed September 20, 2019)
        • Shenoy E.S.
        • Pierce V.M.
        • Walters M.S.
        • et al.
        Transmission of mobile colistin resistance (mcr-1) by duodenoscope.
        Clin Infect Dis. 2019; 68: 1327-1334
        • Verfaillie C.L.
        • Bruno M.J.
        • Voor in ’t holt A.F.
        • et al.
        Withdrawal of a novel-design duodenoscope ends outbreak of a VIM-2-producing Pseudomonas aeruginosa.
        Endoscopy. 2015; 47: 493-502
        • Wendorf K.A.
        • Kay M.
        • Baliga C.
        • et al.
        Endoscopic retrograde cholangiopancreatography-associated AmpC Escherichia coli outbreak.
        Infect Control Hosp Epidemiol. 2015; 36: 634-642
      1. US Food and Drug Administration (FDA). Design of Endoscopic Retrograde Cholangiopancreatography (ERCP) Duodenoscopes May Impede Effective Cleaning: FDA Safety Communication. Date Issued: February 19, 2015. http://wayback.archive-it.org/7993/20170722213105/https://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm434871.htm. Accessed September 20, 2019.

        • Humphries R.M.
        • Yang S.
        • Kim S.
        • et al.
        Duodenoscope-Related Outbreak of a Carbapenem-Resistant Klebsiella pneumoniae Identified Using Advanced Molecular Diagnostics.
        Clin Infect Dis. 2017; 65: 1159-1166
        • Muscarella L.F.
        Use of ethylene-oxide gas sterilization to terminate multidrug-resistant bacterial outbreaks linked to duodenoscopes.
        BMJ Open Gastroenterol. 2019; 6e000282
        • Centers for Disease Control and Prevention (CDC)
        Guideline for Disinfection and Sterilization in Healthcare Facilities.
        2008 (Accessed September 20, 2019)
        • Petersen B.T.
        • Cohen J.
        • Hambrick R.D.
        • et al.
        Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update. ASGE Reprocessing Guideline Task Force.
        Gastrointest Endosc. 2017; 85: 282-294
        • American Society of Gastrointestinal Endoscopy (ASGE)
        ASGE guideline for infection control during GI endoscopy.
        Gastrointest Endosc. 2018; 87 (Accessed September 20, 2019): 1167-1179
        • Alrabaa S.F.
        • Nguyen P.
        • Sanderson R.
        • et al.
        Early identification and control of carbapenemase-producing Klebsiella pneumoniae, originating from contaminated endoscopic equipment.
        Am J Infect Control. 2013; 41: 562-564
        • Cêtre J.C.
        • Nicolle M.C.
        • Salord H.
        • Pérol M.
        • Tigaud S.
        • David G.
        • Bourjault M.
        • Vanhems P.
        Outbreaks of contaminated broncho-alveolar lavage related to intrinsically defective bronchoscopes.
        J Hosp Infect. 2005; 61: 39-45
      2. US Food and Drug Administration (FDA). Supplemental Measures to Enhance Duodenoscope Reprocessing: FDA Safety Communication. Date issued: August 4, 2015. http://wayback.archive-it.org/7993/20170722150658/https://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm454766.htm. Accessed September 20, 2019.

        • US Food and Drug Administration (FDA)
        Infections Associated with Reprocessed Flexible Bronchoscopes: FDA Safety Communication.
        Date Issued: September 17,. 2015; (Accessed September 20, 2019)
        • Ofstead C.L.
        • Quick M.R.
        • Wetzler H.P.
        • et al.
        Effectiveness of Reprocessing for Flexible Bronchoscopes and Endobronchial Ultrasound Bronchoscopes.
        Chest. 2018; 154: 1024-1034
        • Association for the Advancement of Medical Instrumentation (AAMI)
        Strong Evidence for Sterilization of Endoscopes Presented at Stakeholder Meeting.
        Posted September 13,. 2017;
        • US Food and Drug Administration (FDA)
        Regulatory report number: 2951238-2014-00662.
        Date FDA received: December 24,. 2014; (Accessed September 20, 2019)
        • Klefisch F.R.
        • Schweizer C.
        • Kola A.
        • et al.
        A flexible bronchoscope as a source of an outbreak with OXA-48 carbapenemase producing Klebsiella pneumoniae.
        Hyg Med. 2015; 40: 1-6
      3. US Food and Drug Administration (FDA). Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling. Guidance for Industry and Food and Drug Administration Staff. March 17, 2015. Pages 1-40. https://www.fda.gov/media/80265/download Accessed September 20, 2019.

        • Alipour N.
        • Karagoz A.
        • Taner A.
        • et al.
        Outbreak of Hospital Infection from Biofilm-embedded Pan Drug-resistant Pseudomonas aeruginosa Due to a Contaminated Bronchoscope.
        J Prev Med. 2017; 2: 1-9
        • Galdys A.L.
        • Marsh J.W.
        • Delgado E.
        • et al.
        Bronchoscope-associated clusters of multidrug-resistant Pseudomonas aeruginosa and carbapenem-resistant Klebsiella pneumoniae.
        Infect Control Hosp Epidemiol. 2018; : 1-7
      4. US Food and Drug Administration (FDA). Olympus BF-UC180F model. Voluntary manufacturer recall. Z-3304-2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfRes/res.cfm?id=167017. Accessed September 20, 2019.

      5. US Food and Drug Administration (FDA). Manufacturer and User Facility Device Experience (MAUDE) database. https://www.fda.gov/medical-devices/mandatory-reporting-requirements-manufacturers-importers-and-device-user-facilities/manufacturer-and-user-facility-device-experience-database-maude. Accessed September 20, 2019.

      6. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2016-00571. Date FDA received: July 1, 2016. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=5766935&pc=EOQ. Accessed September 20, 2019.

        • Alvarado C.J.
        • Stolz S.M.
        • Maki D.G.
        Nosocomial infections from contaminated endoscopes: a flawed automated endoscope washer. An investigation using molecular epidemiology.
        Am J Med. 1991; 91: 272S-280S
        • US Food and Drug Administration (FDA)
        Regulatory report number: 2951238-2019-00379.
        Date FDA received: January 18,. 2019; (Accessed September 20, 2019)
        • Fraser V.J.
        • Jones M.
        • Murray P.R.
        • et al.
        Contamination of flexible fiberoptic bronchoscopes with Mycobacterium chelonae linked to an automated bronchoscope disinfection machine.
        Am Rev Respir Dis. 1992; 145: 853-855
      7. Centers for Disease Control and Prevention (CDC). Carbapenem-resistant Enterobacteriaceae (CRE) Infection: Clinicians FAQs. Updated: February 25, 2015. https://www.cdc.gov/hai/organisms/cre/cre-clinicianfaq.html. Accessed September 20, 2019.

        • Kizny Gordon A.E.
        • Mathers A.J.
        • Cheong E.Y.L.
        • et al.
        The hospital water environment as a reservoir for carbapenem-resistant organisms causing hospital-acquired infections-a systematic review of the literature.
        Clin Infect Dis. 2017; 64: 1435-1444
      8. US Food and Drug Administration (FDA). Regulatory report number: MW5079139. Date FDA received: August 14, 2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=7784255&pc=EOQ. Accessed September 20, 2019.

      9. US Food and Drug Administration. Olympus BF-160 model. Voluntary manufacturer recall. Z-3283-2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfRes/res.cfm?id=166996. Accessed September 20, 2019.

      10. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2014-00417. Date FDA received: August 28, 2014. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=4101724&pc=EOQ. Accessed September 20, 2019.

      11. US Food and Drug Administration (FDA). Olympus BF-1T180 model. Voluntary manufacturer recall. Z-3285-2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfRES/res.cfm?id=166998. Accessed September 20, 2019.

      12. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2016-00826. Date FDA received: November 3, 2016. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=6077932&pc=EOQ. Accessed September 20, 2019.

      13. US Food and Drug Administration (FDA). Regulatory report number: MW5065337. Date FDA received: October 11, 2016. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=6021641&pc=EOQ. Accessed September 20, 2019.

      14. US Food and Drug Administration (FDA). Regulatory report number: 9610877-2016-00171. Date FDA received: October 6, 2016. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=6004943&pc=EOQ. Accessed September 20, 2019.

        • US Food and Drug Administration (FDA)
        Pentax FB-10V and FB-18BS models.
        (Voluntary manufacturer recall: Z-2065-2016)2016 (Accessed September 20, 2019)
      15. US Food and Drug Administration (FDA). Regulatory report number: 8010047-2017-01927. Date FDA received: December 6, 2017. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=7085891&pc=EOQ. Accessed September 20, 2019.

      16. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2018-00326. Date FDA received: May 31, 2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=7559224&pc=EOQ. Accessed September 20, 2019.

      17. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2018-00730. Date FDA received: November 29, 2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=8118314&pc=EOQ. Accessed September 20, 2019.

      18. US Food and Drug Administration (FDA). Regulatory report number: 2951238-2018-00731. Date FDA received: November 29, 2018. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/detail.cfm?mdrfoi__id=8118320&pc=EOQ. Accessed September 20, 2019.

        • Mehta A.C.
        • Prakash U.B.
        • Garland R.
        • et al.
        American College of Chest Physicians and American Association for Bronchology Consensus Statement: Prevention of Flexible Bronchoscopy-Associated Infection: 2005.
        Chest. 2005; 128: 1742-1755
        • Kovaleva J.
        • Peters F.T.M.
        • van der Mei H.C.
        • et al.
        Transmission of Infection by flexible gastrointestinal endoscopy and bronchoscopy.
        Clin Microbiol Rev. 2013; 26: 231-254
        • Guy M.
        • Vanhems P.
        • Dananché C.
        • et al.
        Outbreak of pulmonary Pseudomonas aeruginosa and Stenotrophomonas maltophilia infections related to contaminated bronchoscope suction valves, Lyon, France, 2014.
        Euro Surveill. 2016; 21
      19. Olympus Corporation of the Americas. Urgent Medical Device Safety Notice. August 8, 2018. https://www.zva.gov.lv/sites/default/files/inline-files/FSN_Olympus.pdf. Accessed September 20, 2019.

        • Srinivasan A.
        • Wolfenden L.L.
        • Song X.
        • et al.
        An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes.
        N Engl J Med. 2003; 348: 221-227
        • Kirschke D.L.
        • Jones T.F.
        • Craig A.S.
        • et al.
        Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes.
        N Engl J Med. 2003; 348: 214-220
        • Srinivasan A.
        • Perl T.M.
        • Schaffner W.
        • et al.
        Outbreaks of Infection Associated with Bronchoscopes.
        N Engl J Med. 2003; 348: 2039-2040
      20. Olympus. Urgent Field Safety Notice. October X, 2018. Reference no. QIL 151-006. https://www.zva.gov.lv/sites/default/files/inline-files/FSN_Olympus.pdf. Accessed September 20, 2019.

        • Muscarella L.F.
        Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
        Am J Gastroenterol. 2006; 101: 2147-2154
      21. Centers for Disease Control and Prevention (CDC). Essential Elements of a Reprocessing Program for Flexible Endoscopes—Recommendations of the Healthcare Infection Control Practices Advisory Committee. Last update: January 25, 2017. PP. 1-12. https://www.cdc.gov/hicpac/pdf/flexible-endoscope-reprocessing.pdf. Accessed September 20, 2019.

        • Mehta A.
        • Gilda T.
        Burying our heads in the sand. Cross-contamination during bronchoscopy.
        Chest. 2018; 154: 1001-1003
        • Centers for Disease Control and Prevention (CDC)
        Nosocomial infection and pseudoinfection from contaminated endoscopes and bronchoscopes—Wisconsin and Missouri.
        MMWR Morb Mortal Wkly Rep. 1991; 40 (Accessed September 20, 2019): 675-678
        • Parr A.
        • Querry A.
        • Pasculle A.
        • et al.
        Carbapenem-resistant Klebsiella pneumoniae cluster associated with gastroscope exposure among surgical intensive care unit patients at University of Pittsburgh Medical Center.
        Open Forum Infect Dis. 2016; 3: 248
        • Thaker A.M.
        • Kim S.
        • Sedarat A.
        • et al.
        Inspection of endoscope instrument channels after reprocessing using a prototype borescope.
        Gastrointest Endosc. 2018; 88: 612-619
      22. Olympus America, Inc. A “Dear Health Care Professional” letter regarding use of borescopes for cleaning verification of flexible endoscopes. [Letter] December 8, 2017. https://medical.olympusamerica.com/sites/default/files/us/files/pdf/Borescope-Use-with-Olympus-Flexible-Endoscopes.pdf. Accessed September 20, 2019.

        • Wang P.
        • Xu T.
        • Ngamruengphong S.
        • et al.
        Rates of infection after colonoscopy and osophagogastroduodenoscopy in ambulatory surgery centres in the USA.
        Gut. 2018; 67: 1626-1636
        • Culver D.A.
        • Gordon S.M.
        • Mehta A.C.
        Infection control in the bronchoscopy suite. A review of outbreaks and guidelines for prevention.
        Am J Respir Crit Care Med. 2003; 167: 1050-1056
        • Schelenz S.
        • French G.
        An outbreak of multidrug-resistant Pseudomonas aeruginosa infection associated with contamination of bronchoscopes and an endoscope washer-disinfector.
        J Hosp Infect. 2000; 46: 23-30
        • Sorin M.
        • Segal-Maurer S.
        • Mariano N.
        • et al.
        Nosocomial transmission of imipenem-resistant Pseudomonas aeruginosa following bronchoscopy associated with improper connection to the Steris System 1 processor.
        Infect Control Hosp Epidemiol. 2001; 22: 409-413
        • Muscarella L.F.
        The importance of bronchoscope reprocessing guidelines: raising the standard of care.
        Chest. 2004; 126: 1001-1002
        • Blanc D.S.
        • Parret T.
        • Janin B.
        • et al.
        Nosocomial infections and pseudoinfections from contaminated bronchoscopes: two-year follow up using molecular markers.
        Infect Control Hosp Epidemiol. 1997; 18: 134-136
        • Shimono N.
        • Takuma T.
        • Tsuchimochi N.
        • et al.
        An outbreak of Pseudomonas aeruginosa infections following thoracic surgeries occurring via the contamination of bronchoscopes and an automatic endoscope reprocessor.
        J Infect Chemother. 2008; 14: 418-423
        • Srinivasan A.
        • Wolfenden L.L.
        • Song X.
        • et al.
        Bronchoscope reprocessing and infection prevention and control: bronchoscopy-specific guidelines are needed.
        Chest. 2004; 125: 307-314
        • Ofstead C.L.
        • Dirlam Langlay A.M.
        • Mueller N.J.
        • et al.
        Re-evaluating endoscopy-associated risk estimates and their implications.
        Am J Infect Control. 2013; 41: 734-736
      23. Centers for Disease Control and Prevention (CDC). Interim Duodenoscope Surveillance Protocol. March 2015.

      24. US Food and Drug Administration (FDA), Centers for Disease Control and Prevention (CDC) and American Society for Microbiology (ASM). Duodenoscope surveillance sampling and culturing. Reducing the risks of infection. February 2018:1-57. https://www.fda.gov/media/111081/. Accessed September 20, 2019.

        • McGrath B.A.
        • Ruane S.
        • McKenna J.
        • et al.
        Contamination of single-use bronchoscopes in critically ill patients.
        Anaesthesia. 2017; 72: 36-41
        • Zaidi S.R.
        • Collins A.M.
        • Mitsi E.
        • et al.
        Single use and conventional bronchoscopes for bronchoalveolar lavage (BAL) in research: a comparative study (NCT 02515591).
        BMC Pulm Med. 2017; 17: 83